Kramer-electronics VS-66FW Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Směrovače Kramer-electronics VS-66FW. Kramer Electronics VS-66FW User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - USER MANUAL

Kramer Electronics, Ltd. USER MANUAL Model: VS-66FW 6 Port FireWire Switcher

Strany 2 - Contents

KRAMER: SIMPLE CREATIVE TECHNOLOGYDefining the VS-66FW 6 Port FireWire Switcher 6 Figure 3: VS-66FW 6 Port FireWire Switcher

Strany 3

Defining the VS-66FW 6 Port FireWire Switcher 7Table 1: Front Panel VS-66FW 6 Port FireWire Switcher Features # Feature Function 1 IR Receiver Th

Strany 4 - ADDENDUM: VS-66FW

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the VS-66FW 8 5 Connecting the VS-66FW This section describes how to connect the VS-66FW. In particu

Strany 5 - 3 Overview

Connecting the VS-66FW 9 Figure 4: Connecting the VS-66FW 6 Port FireWire Switcher 5.2 Controlling via RS-232 (for example, using a PC) To connect a

Strany 6 - Overview

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the VS-66FW 10 5.3 Controlling via RS-485 You can control a VS-66FW unit via any RS-485 remote contr

Strany 7 - 3.3.2 Signal Terminology

Connecting the VS-66FW 115.4.1 Setting the MACHINE # The MACHINE # determines the position of a VS-66FW unit, specifying which VS-66FW unit is being

Strany 8

KRAMER: SIMPLE CREATIVE TECHNOLOGY Operating the VS-66FW 12 6 Operating the VS-66FW You can operate your VS-66FW via:  The front panel buttons 

Strany 9

Operating the VS-66FW 136.2 Switching LEAF- BRANCH Combinations To switch a BRANCH FireWire device to a LEAF FireWire device (a bi-directional conne

Strany 10 -

KRAMER: SIMPLE CREATIVE TECHNOLOGY Operating the VS-66FW 14 6.3.1 Toggling between the AT ONCE and CONFIRM Modes To toggle between the AT ONCE and

Strany 11

Operating the VS-66FW 156.4.1 Storing an Input/Output Configuration To store1 the current status in memory, do the following: 1. Press the STO butt

Strany 12 - 5 Connecting the VS-66FW

Contents iContents 1 Introduction 1 2 Getting Started 1 3 Overview 1 3.1 Understanding FireWire 2 3.2 FireWire Compliance 2 3.3 Your VS-66FW 6 P

Strany 13 - Connecting the VS-66FW

KRAMER: SIMPLE CREATIVE TECHNOLOGY Flash Memory Upgrade 16 7 Flash Memory Upgrade The VS-66FW firmware is located in FLASH memory, which lets you

Strany 14 - Table 3: Dipswitch Settings

Flash Memory Upgrade 17 Figure 10: Splash Screen 2. After a few seconds, the Splash screen is replaced by the “Atmel – Flip” window: Figure 11: Atm

Strany 15 - Figure 7: REMOTE Connector

KRAMER: SIMPLE CREATIVE TECHNOLOGY Flash Memory Upgrade 18  Figure 12: Open Configuration File Select Window 4. Choose the

Strany 16 - 6 Operating the VS-66FW

Flash Memory Upgrade 19 Figure 14: RS-232 Window 6. Click Connect. In the “ Atmel – Flip” window, in the Operations Flow column, the Run button is a

Strany 17 - Operating the VS-66FW

KRAMER: SIMPLE CREATIVE TECHNOLOGY Flash Memory Upgrade 20  Figure 16: Atmel – Flip Window (Operation Completed) 8. Close the “Atme

Strany 18

Technical Specifications 218 Technical Specifications Table 5 includes the technical specifications: Table 5: Technical Specifications1 of the VS-6

Strany 19

KRAMER: SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 2000 22 10 Kramer Protocol 20001 The VS-66FW is compatible with Kramer’s Protocol 2000 (version

Strany 20 - 7 Flash Memory Upgrade

Kramer Protocol 2000 23For a single machine controlled via the serial port, always set M4…M0 = 1, and make sure that the machine

Strany 21 - Figure 10: Splash Screen

KRAMER: SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 2000 24 NOTE 6 – If INPUT is set to 127 for these instructions, then, if the function

Strany 22

Kramer Protocol 2000 25then, after the required delay, send HEX codes 07 80 C1 81 (execute delayed switch) to implement the switch. NOTE 18 – Af

Strany 23 - Figure 14: RS-232 Window

KRAMER: SIMPLE CREATIVE TECHNOLOGY Contents ii Figures Figure 1: Configuring the VS-66FW as a 2x2 Port FireWire Hub 4 Figure 2: Configuring the VS-

Strany 24

KRAMER: SIMPLE CREATIVE TECHNOLOGY 26 LIMITED WARRANTY Kramer Electronics (hereafter Kramer) warrants this product free from defects in

Strany 25 - 8 Technical Specifications

Kramer Electronics, Ltd. Web site: www.kramerelectronics.com E-mail: [email protected] P/N: 2900-000066 REV 1 For the latest informa

Strany 26 - 10 Kramer Protocol 2000

P/N: 2900-0000662 A1 ADDENDUM: VS-66FW This addendum updates the VS-66FW user manual, a

Strany 27 - Kramer Protocol 2000

Introduction 11 Introduction Welcome to Kramer Electronics (since 1981): a world of unique, creative and affordable solutions to the infinite range

Strany 28

KRAMER: SIMPLE CREATIVE TECHNOLOGY Overview 2 3.1 Understanding FireWire FireWire is a serial bus standard that enables quick universal interfacing

Strany 29

Overview 33.3 Your VS-66FW 6 Port FireWire Switcher The Kramer VS-66FW is a high quality 6-port matrix switcher for routing 1394/FireWire interface

Strany 30

KRAMER: SIMPLE CREATIVE TECHNOLOGY Overview 4 not merely one of semantics but a vital distinction when understanding the concept of FireWire Branch/

Strany 31 - P/N: 2900-000066 REV 1

Defining the VS-66FW 6 Port FireWire Switcher 53.3.3.2 Configuring as a 6 Port FireWire Hub The example in Figure 2 illustrates how the VS-66FW can b