Kramer-electronics PL-50 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Kontrolní panel Kramer-electronics PL-50. Kramer Electronics PL-50 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - USER MANUAL

Kramer Electronics, Ltd. USER MANUAL Model: PL-50 Power Controller - Monitor

Strany 2

KRAMER: SIMPLE CREATIVE TECHNOLOGY Your PL-50 Power Controller - Monitor 6 Table 2: PL-50 Power Controller – Monitor Features # Feature Function 1

Strany 3 - 10.7 Instruction Codes 43

Installing in a Rack 7 5 Installing in a Rack This section describes what to do before installing in a rack and how to rack mount. Before Installin

Strany 4

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 8 6 Connecting the PL-50 Power Controller - Monitor To connect t

Strany 5 - 2 Getting Started

Connecting the PL-50 Power Controller - Monitor 9 6.1 Connecting the Relays Figure 5 shows how to connect the relay. To Alarm Figure 5: Relay Wirin

Strany 6 - Getting Started

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 10 5. Select the Internet Protocol (TCP/IP) and click the Proper

Strany 7 - 3 Overview

Connecting the PL-50 Power Controller - Monitor 11 6.2.3 Configuring the Ethernet Port Initially To initially configure the Ethernet port, download

Strany 8 - Definition

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 12 Figure 9: Connect Screen 3. Connect a USB cable from a USB p

Strany 9

Connecting the PL-50 Power Controller - Monitor 13 6.3 Controlling via the Embedded Web Pages The embedded Web page can be used to remotely operate

Strany 10 - 1 OC means Open Collector

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 14 Check that Java and JavaScript is enabled in your browser. T

Strany 11 - CAUTION!

Connecting the PL-50 Power Controller - Monitor 15 6.3.2 The Panel Screen The Panel screen lets you select one or more channels in order to read th

Strany 12

Contents i Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 1 3 Overview 3 3.1 Terminology Used in this User Manual 4 4 Your

Strany 13 - To Alarm

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 16 6.3.3 The Scheduler Screen The Scheduler screen lets you sche

Strany 14

Connecting the PL-50 Power Controller - Monitor 17 After scheduling the outlets, the Scheduler screen appears as follows: Figure 17: Scheduling the

Strany 15

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 18 6.3.4 The Channel Settings Screen Figure 18 and Table 5 defin

Strany 16 - Figure 9: Connect Screen

Connecting the PL-50 Power Controller - Monitor 19 6.3.5 The Alerts Screen Figure 19 and Table 6 define the Alerts screen: Figure 19: The Alerts S

Strany 17

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 20 After setting the alarms, the Alerts screen appears as follows

Strany 18

Connecting the PL-50 Power Controller - Monitor 21 6.3.6 The Power Measurement Screen Figure 21 and Table 7 define the Power Measurement screen: F

Strany 19

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 22 6.3.7 The Power ON/OFF Order Screen The Power ON/OFF Order sc

Strany 20 - 6.3.3 The Scheduler Screen

Connecting the PL-50 Power Controller - Monitor 23 In the example illustrated in Figure 23, the Power OFF Order is set from 5 to 1 with a 10 second

Strany 21

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 24 6.3.8 The Configurations Screen The Configurations page lets

Strany 22

Connecting the PL-50 Power Controller - Monitor 25 If the security system is disabled, the embedded Web pages can be accessed, and the parameters ch

Strany 23

KRAMER: SIMPLE CREATIVE TECHNOLOGY Contents ii 10.7 Instruction Codes 43 Figures Figure 1: PL-50 Power Controller – Monitor Front Panel 5 Figure

Strany 24

KRAMER: SIMPLE CREATIVE TECHNOLOGY Connecting the PL-50 Power Controller - Monitor 26 6.3.8.1 The Security System Set the user password and Admin p

Strany 25

Operating Your PL-50 Power Controller – Monitor 27 6.4 DIP-switch Settings Figure 29 and Table 9 define the DIP-switches: 1 2 Table 9: DIP-switch

Strany 26

KRAMER: SIMPLE CREATIVE TECHNOLOGY Operating Your PL-50 Power Controller – Monitor 28 To set the Standby mode11. Press one or more OUT buttons to s

Strany 27

Flash Memory Upgrade 29 8 Flash Memory Upgrade The PL-50 uses a microcontroller that runs firmware located in FLASH memory. The latest version of f

Strany 28

KRAMER: SIMPLE CREATIVE TECHNOLOGY Flash Memory Upgrade 30 8.1.3 Update the Firmware To update the firmware, perform the following steps: 1. Open

Strany 29

Flash Memory Upgrade 31 3. If you are upgrading using an Ethernet connection, check Ethernet. To reset the device address to the factory default a

Strany 30

KRAMER: SIMPLE CREATIVE TECHNOLOGY Flash Memory Upgrade 32 Figure 33: K-UPLOAD Connected Note: In the Device Properties section, you can update any

Strany 31

Flash Memory Upgrade 33 6. Click the UPLOAD button to begin the file transfer. The Warning window appears: Figure 35: Warning Window 7. Click OK

Strany 32

KRAMER: SIMPLE CREATIVE TECHNOLOGY Flash Memory Upgrade 34 8. When the update is finished, the restart message appears: Figure 37: Restart Messag

Strany 33 - 8 Flash Memory Upgrade

Technical Specifications 35 8.2 Changing the Device Parameters To change the device parameters do the following: 1. Connect a PC to the PL-50 (see

Strany 34 - Flash Memory Upgrade

Contents iii Tables Table 1: Terminology Used in this User Manual 4 Table 2: PL-50 Power Controller – Monitor Features 6 Table 3: Relay PINOUT 9 T

Strany 35

KRAMER: SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 3000 36 10 Kramer Protocol 3000 The Ethernet/USB/RS-232/RS-4851 communication protocol210.1 Pr

Strany 36

Kramer Protocol 3000 37 10.2 Command Terms Command: Sequence of ASCII letters ('A'-'Z', 'a'-'z' and '

Strany 37 - 7. Click OK to continue

KRAMER: SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 3000 38 10.3 Common Commands # Cmd Short Description Command Type Permission Protocol ha

Strany 38 - Figure 37: Restart Message

Kramer Protocol 3000 39 FACTORY Cmd Short Description Command Type Permission Reset to factory default config Common Administrator Usage:

Strany 39 - 9 Technical Specifications

KRAMER: SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 3000 40 UPGRADE Cmd Short Description Command Type Permission Execute firmware upgrade Com

Strany 40 - 10 Kramer Protocol 3000

Kramer Protocol 3000 41 PASS Cmd Short Description Command Type Permission Set password Security Administrator Usage: Syntax Respons

Strany 41 - CR , press the Enter

KRAMER: SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 3000 42 NET-DHCP Cmd Short Description Command Type Permission NTDH Set DHCP mode Ethernet

Strany 42 - 10.3 Common Commands

Kramer Protocol 3000 43 NET-MAC? Cmd Short Description Command Type Permission NTMC? Read MAC address Ethernet End User Usage: Syntax

Strany 43 - Kramer Protocol 3000

KRAMER: SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 3000 44 ALARM-OFF Cmd Short Description Command Type Permission Set alarm OFF PL-50 User

Strany 44 - 10.5 23BSecurity Commands

Kramer Protocol 3000 45 ALERT-REG? Cmd Short Description Command Type Permission Query Alert Registration PL-50 User Usage: Syntax R

Strany 45

Introduction 1 1 1 Introduction Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and af

Strany 46

KRAMER: SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 3000 46 SWITCH? Cmd Short Description Command Type Permission Query channel switch PL-50

Strany 47 - 10.7 Instruction Codes

47 LIMITED WARRANTYWHO IS PROTECTED?WHAT IS COVERED AND WHAT IS NOT COVEREDWHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FORHOW YOU CAN GET WARRANT

Strany 48

Kramer Electronics, Ltd. Web site: www.kramerelectronics.com E-mail: [email protected] P/N: 2900-000576 REV 4 For the latest information o

Strany 49

KRAMER: SIMPLE CREATIVE TECHNOLOGY Getting Started 2

Strany 50

Overview 3 3 3 Overview The PL-50 Power Controller Monitor can control up to five power channels at a total load of 10A. The PL-50, by measuring and

Strany 51

KRAMER: SIMPLE CREATIVE TECHNOLOGY Your PL-50 Power Controller - Monitor 4 3.1 Terminology Used in this User Manual Table 1 defines some terms that

Strany 52

Your PL-50 Power Controller - Monitor 5 Figure 1: PL-50 Power Controller – Monitor Front Panel Figure 2: PL-50 Power Controller – Monitor (for Euro